Valvula electrica 1"

ELECTROVALVULA 1" BERMAD/CEPEX 210 2W EST 24VAC NC EXTR. B Adicionar a Favoritos
CEPEX - FLUIDRA
Codigo: 00000783

Valvula electrica (Electrovalvula) roscas hembra 1" - 24 VAC

Precio actual $ 35.50 + 0% IVA

Variantes de este producto:

Valvula eléctrica

Marca: Cepex / Bermad

Roscas disponibles:  1", 1 1/2", 2"

Fuente electrica: 24 VAC


Nuevo Comentario

Entra para poder comentar

Catalogo valvula electrica Cepex

Descargar

Catalogo detallado valvula electrica Cepex

Descargar

Valvula eléctrica

Marca: Cepex / Bermad

Roscas disponibles:  1", 1 1/2", 2"

Fuente electrica: 24 VAC


CEPEX ELECTRIC VALVES CPV
APPLICATION Residential, commercial, agriculture
SIZES ¾”, 1”, 1½”, 2”, 3” BSP female
OPTIONS 24 VAC / 9 V latch
MINIMUM FLOW 0,5 m3/h
WORKING PRESSURE 0,7 - 10 bar
MATERIAL Nylon reinforced
CONTROL Electric - solenoid 2 ways
FLOW CONTROL YES
OTHER CHARACTERISTICS Without pipes or external accessories
Compact construction
Bolt closing cover
Self cleaning hole
BERMAD Irrigation
4
2-Way Solenoid Controlled, Normally Closed (N.C.)
Principle of Operation
Closed Position
The restriction continuously allows line pressure
into the control chamber. The solenoid controls outflow
from the control chamber. When the solenoid is
closed it causes pressure to accumulate in the control
chamber, therefor forcing the valve to close.
Open Position
the Solenoid releases more flow from the
control chamber than the restriction can allow in.
This causes the accumulated pressure in the control
chamber to drop, enabling the line pressure acting on
the plug to the valve.
3-Way Solenoid Controlled, Normally Open (N.O.)
Open Position
The de-energized solenoid blocks the valve internal
line pressure inlet and opens the drain port, venting
the control chamber to the atmosphere, therefor fully
opening the valve.
Closed Position
Energizing the solenoid opens the internal line pressure
inlet and blocks the drain port. This pressurizes the
control chamber, closing the valve.
OFF
OFF
ON
ON
200 Series
Closed Position
The internal restriction continuously allows line pressure
into the control chamber. The solenoid controls
outflow from the control chamber. When the solenoid
is closed it causes pressure to accumulate in the
control chamber, therefor forcing the valve to close.
Open Position
Opening the Solenoid releases more flow from the
control chamber than the restriction can allow in.
This causes the accumulated pressure in the control
chamber to drop, enabling the line pressure acting
on the plug to the valve.
Solenoid
Control chamber
Membrane
Solenoid
Control chamber
Membrane
COMPONENT MATERIAL
1 Bolts and nuts Stainless steel
2 Solenoid
3 Manual override handle Nylon reinforced
4 Needle
5 Flow control Nylon reinforced
6 Auxiliary closing spring Stainless steel
7 Diaphragm NBR
8 Internal restriction
9 Body Nylon reinforced
10 Internal control circuit outlet
COMPONENTS
CHARACTERISTICS
OPERATION
www.cepexirrigation.com
3
DN80
PRESSURE LOSS DIAGRAMM
DN20 - ¾” DN25 - 1” DN40 - 1½” DN50 - 2” DN80 - 3”
Kv (m3/h) 9 10,5 37 47 100
R
H
L
W
R
H
L
W
H(T)
L(T)
L(F)
H(F)
W
h